PizarraContexto de trabajoDocumentos y registrosControles críticosRegistrosPreparaciónCondiciones bloqueantesAutorización
Aseguramiento / Técnico
Phase 1 prototype · Phase 2A corrective verification · SYNTHETIC DEMONSTRATION DATA

Integrated Preventive Readiness

Hold point — Phase 3 not authorized
Acting role — demonstration device only, not an authorization mechanism

Superintendent: What will be ready across my area, and what must be resequenced?

3100-CONC-CV07-TT01 · context v7

Concentrator — CV-07 Transfer Tower 01, Level +12 m

ACTIVECONTINUITY CONTINUOUS
Register authority
Canonical Location Register (readiness-owned, ADR-14 Option C)
Parent
LOC-3100-CONC
Concurrent work set
WS-2026-09-02-TT01
Location SIMOPS verdict
STOP

Active Job Cards

in preparation or authorized
  • JC-7701 CV-07 head pulley bearing replacement
    MECHANICALSTOPPREPARING
  • JC-7702 MCC-3100-B feeder termination and loop power-up
    ELECTRICALCONDITIONALAUTHORIZED

Upcoming Job Cards

planned within the lookahead
  • JC-7703 CV-07 belt-drift and speed instrumentation loop check
    INSTRUMENTATIONHOLD

Equipment context

location-owned, never authorization
CV-07Transfer conveyor CV-07ISOLATEDISO-CV07-A
MCC-3100-BMotor control centre BELECTRICAL LIVE
TT01-GANTRYTransfer tower gantry crane (shared)AVAILABLE

Location Critical Risk Context

origin: location — distinct from activity risk
  • LCR-02Working at heightLOCATION
  • LCR-05Energy isolationLOCATION
  • LCR-07Lifting operationsLOCATION

Restrictions

active location restrictions
RST-441ACTIVE

Gantry lifting prohibited while personnel occupy the +12 m grating

Owner: Area Manager

Environmental conditions

federated, read-only source
ENV-19BREACH FORECAST

Wind gust forecast 21 m/s at +12 m between 13:00–17:00

Threshold: Lifting suspended > 15 m/s · Source: Site Met (federated, read-only)

Lessons

location lesson register

LL-2211Prior near-miss: dropped object during transfer-tower lift with concurrent grating work

Work-control transactions in this location

associated, never inherited
  • PTW-99201PTWQ4: In ReviewHOLDJC-7701
  • PETAR-4410PETARQ4: GeneratedHOLDJC-7701
  • ISO-CV07-AISOLATIONQ4: AppliedREADYJC-7701
  • PTW-99205PTWQ4: AuthorizedREADYJC-7702
  • JHA-3320JHAQ4: LockedUNMAPPED STATEJC-7702
  • PETAR-4415PETARQ4: DraftHOLDJC-7703

Blocker attribution — what is blocking which job, why and who must act

Location is an aggregate operational context — control ownership remains with the Job Card

Job CardDisciplineBlockerTypeStatementConsequenceOwnerRequired actionRequired byEvidence
JC-7701MechanicalSIMOPS-LOCSIMOPS CUMULATIVESIMOPS CUM-3 — lifting envelope overlaps occupied grating (RST-441)STOPShift SIMOPS CoordinatorRemove the causing concurrent condition or resequence; STOP is non-compensable2026-09-02 05:00EV-2A-BLK-JC-7701-SIMOPS
JC-7701MechanicalEC-02ENABLING CONDITIONRigger competency current for all lift crew — EXPIRINGCONDITIONALTraining CoordinatorRenew rigger competency or replace crew member before lift window2026-09-02 06:00EV-2A-BLK-JC-7701-EC-02
JC-7701MechanicalEC-04ENABLING CONDITIONWind speed below 15 m/s at working level — NOT_SATISFIEDHOLDShift SuperintendentRe-forecast wind and reschedule lifting outside the breach window2026-09-02 13:00EV-2A-BLK-JC-7701-EC-04
JC-7701MechanicalEC-06ENABLING CONDITIONDropped-object exclusion barricade erected at +8 m — NOT_SATISFIEDHOLDSupervisor — MechanicalErect dropped-object exclusion barricade at +8 m and field-verify2026-09-02 06:30EV-2A-BLK-JC-7701-EC-06
JC-7702ElectricalSIMOPS-LOCSIMOPS CUMULATIVEConcurrent energised work while CV-07 isolation boundary is shared (CUM-1)STOPIsolation AuthorityRemove the causing concurrent condition or resequence; STOP is non-compensable2026-09-02 05:30EV-2A-BLK-JC-7702-SIMOPS
JC-7702ElectricalEC-11ENABLING CONDITIONArc-flash PPE certification current for all crew — EXPIRINGCONDITIONALTraining CoordinatorRenew arc-flash PPE certification for the two affected persons2026-09-02 05:00EV-2A-BLK-JC-7702-EC-11
JC-7702ElectricalEC-15ENABLING CONDITIONBoundary segregation from ISO-CV07-A confirmed by Isolation Authority — UNVERIFIABLEHOLDIsolation AuthorityIsolation Authority to confirm boundary segregation from ISO-CV07-A2026-09-02 05:30EV-2A-BLK-JC-7702-EC-15
JC-7702ElectricalJHA-3320WORK CONTROL STATEQ4 state “Locked” is not in the governed mapping table — fails closedHOLDGovernance Administrator (CA-03)Governed mapping decision required (CA-03); no default state may be assumed2026-09-02 05:30EV-2A-BLK-JC-7702-JHA-3320
JC-7703InstrumentationSIMOPS-LOCSIMOPS CUMULATIVERequirement REQ-INST-114 has CLASSIFICATION_UNRESOLVED — fails closedSTOPFunctional Owner — InstrumentationRemove the causing concurrent condition or resequence; STOP is non-compensable2026-09-02 08:00EV-2A-BLK-JC-7703-SIMOPS
JC-7703InstrumentationEC-22CLASSIFICATIONREQ-INST-114 criticality classified by Functional Owner — UNVERIFIABLEHOLDFunctional Owner — InstrumentationFunctional Owner to classify REQ-INST-114 criticality (CA-04)2026-09-02 08:00EV-2A-BLK-JC-7703-EC-22
JC-7701STOPJob Card verdict STOP → effective STOP · 4 blocker(s)CONSISTENT
JC-7702STOPJob Card verdict CONDITIONAL → effective STOP · 4 blocker(s)CONSISTENT
JC-7703STOPJob Card verdict HOLD → effective STOP · 2 blocker(s)CONSISTENT

Location → Job Card → DecisionExplanation must not contradict. Control ownership is not transferred to Location (controlOwnedBy = JOB_CARD for every row).

SIMOPS evaluation

Pairwise results are necessary but not sufficient. Location verdict is derived independently; no averaging or weighting is applied.

Direct pairwise conflicts

necessary but not sufficient
  • JC-7701JC-7702CONFLICT

    Shared isolation boundary ISO-CV07-A with one energised party (P-1)

  • JC-7701JC-7703PASS
  • JC-7702JC-7703PASS

Pairwise PASS never implies location-level PASS (false).

Cumulative location-level determinants

CUM rules · non-compensable
  • CUM-1STOP

    Concurrent conflicting energy states within one isolation boundary

    Job Cards: JC-7701, JC-7702

  • CUM-3STOP

    Overlapping exclusion zones with occupied level below the lift envelope (RST-441, LL-2211)

    Job Cards: JC-7701, JC-7703

  • CUM-4STOP

    Cumulative crew density 17 persons exceeds governed egress threshold of 12 for TT01

    Job Cards: JC-7701, JC-7702, JC-7703

  • CUM-6HOLD

    Cumulative Life Critical control exposure across three disciplines with a single SIMOPS Coordinator

    Job Cards: JC-7701, JC-7702, JC-7703

Location verdict: STOP. A mandatory cumulative conflict cannot be averaged away or offset.

Continuity — discipline handover

Inherit context — never inherit authorization.

Completed work: JC-7690 — CV-07 structural bolt-up (Mechanical, completed 2026-08-31)

Context that continues

applicability revalidated at the receiving node
  • CONTINUESLocation height risk context LCR-02

    Location-owned, applicability revalidated for receiving discipline

  • CONTINUESAccess route and barricade plan

    Location context container

  • CONTINUESEquipment register entry CV-07 (as-left mechanical state)

    Equipment context, version pinned

  • CONTINUESLesson LL-2211

    Location lesson register

Authorization objects — never inherited

  • NOT INHERITEDPTW-99180 (mechanical)

    Authorization object — closes with the work

  • NOT INHERITEDIsolation certificate ISO-CV07-M

    Authorization object — requires new isolation for the new scope

  • NOT INHERITEDSign-on records of mechanical crew

    Person-specific authorization evidence

  • NOT INHERITEDPETAR-4390

    Task-specific high-risk authorization